How to Winterize Sprinklers: Preparation, Shutdown and Service Checks
Turning off the controller does not winterize a system. Record your equipment, remove the water the right way for your setup and know what to ask a service for.
By GardenHelmPublished 5-minute readMore in Irrigation

In this guide
You can blow out your own sprinklers, but only inside tight limits: Rain Bird’s homeowner guide caps air pressure at 50 psi, limits each zone to 2 minutes of air at a time and asks for a compressor delivering 10 to 25 cubic feet per minute. A small shop compressor may not manage that airflow, and Rain Bird warns that a high-pressure, low-volume compressor (it names 120 psi) puts severe stress on every component. If you do not own or rent the right compressor, or your system has a pump, a hard-to-identify backflow assembly or no blow-out connection, hire an irrigation contractor. University of Minnesota turf specialists and Hunter both recommend a professional for the blow-out. Minnesota turf guidance
Whichever route you take, shutting the controller off removes no water. Trapped water that freezes expands, and that is what splits pipes, valves and exposed backflow equipment.
Which method suits your system
Rain Bird’s guide describes three ways to remove water: manual drain valves, automatic drain valves and a compressed-air blow-out. Hunter’s winterization bulletin lays out the same three as different system designs. Look at what you have before you pick one. Manual drains sit at low points on the mainline, and automatic drains open on their own each time the system shuts off, at low points on the lateral lines.
Gravity is the weak link. Colorado State advises against relying on manual or automatic drains, because buried pipe can shift and hold water in humps you cannot see, and because water above the diaphragm inside an electric valve will not run out by itself. It recommends air. Colorado State winterization guidance Timing is local: blow the system out after the growing season ends and before the ground freezes where you live.
Before the air goes on
Run the system once while you can still walk each zone, and note broken or leaking heads, since Minnesota’s guidance lists that check before winterizing. Take pictures of the backflow assembly label, the shutoff valve, the controller and any pump, and write down where each zone’s valve box is. Do the leak test now. Turning water back on after blow-out undoes it.
You also need a way to connect air. Rain Bird’s design calls for a blow-out connection on the mainline as close to the water source as possible, such as a quick-connect fitting, a plugged tee or a capped pipe, and the compressor maker’s instructions govern the hose connection. Add the fitting first if your system lacks one.
Blowing out from the controller
The sequence below follows Rain Bird’s procedure for systems with electric valves. It starts the zones from the controller so you never stand near the pipes while air is moving.
- Put on eye protection. Do not stand over pipes, valves or sprinkler heads at any point while air is flowing.
- Close the mainline shutoff valve.
- Start the zone farthest from the air connection at the controller to relieve water pressure, then attach the compressor hose to the blow-out fitting.
- Set the compressor’s pressure regulator to 50 psi. Rain Bird requires a regulator; Colorado State puts the ceiling at 80 psi for rigid PVC and 50 psi for polyethylene pipe and says to stay under the rating of your sprinkler nozzles, so the lowest figure is the safe one for a mixed or unknown system.
- Turn on the compressor and increase flow gradually until the heads pop up.
- Run no zone for more than 2 minutes at a time, then advance the controller to the next zone. Do not switch the controller off while the compressor is running. Never run the compressor with every zone valve closed.
- Repeat the full round at least twice, until only a fine mist comes from the heads. Rotors with plastic gears use water to lubricate and cool, so a zone running on air alone for long can ruin them.
- Leave one zone running while you shut the compressor off. Let the stored air bleed off before you approach valves or hose, then disconnect.
Colorado State sizes the compressor by dividing a zone’s flow in gallons per minute by 7.5, and treats heads that stay up while air flows as the sign it is big enough. It also runs one zone at a time, because more than one can overheat pipe and fittings, and warns that the whistling can send pets running, so keep children and pets inside while air is on.
If your valves are manual, Rain Bird’s guide has a separate sequence. Use the controller method where you can, because it keeps your body away from the equipment.
Backflow, valves, pump and controller
The backflow preventer is the part most often damaged. Colorado State says a pressure vacuum breaker or reduced-pressure assembly must never be blown out with compressed air, because the heat can melt its internal rubber seals, and it gives each its own draining steps. Identify which type you own before any air moves, keep the mainline shutoff closed, and hire a contractor if your blow-out connection sits upstream of the assembly so air would pass through it. Rain Bird tells you to follow the backflow maker’s winterizing instructions, leave the shutoff valves open after draining, with ball valves at 45 degrees so water cannot sit in the seals, and insulate or heat-tape the device only in extreme conditions. Watts’s specification for one frost-protected model says its relief feature does not protect the entire irrigation system from freezing, so insulation is an addition, not a replacement for draining. Watts 800M4FR specification
Drain the pump and store it indoors, or follow its maker’s instructions. Rain Bird says valves that were blown out with air need no disassembly and should be left in the manual open position for winter; valves that were not blown out must be opened up and drained. Read the maker’s instructions for any flow sensor before air goes on, since high airflow can damage some; Hunter’s Rain-Clik installation card says that rain sensor needs no removal or cover for winter.
Controllers differ by whether a pump is present. For a system with no pump, Rain Bird sets the controller to Off or Rain and leaves it plugged in, because the warmth inside the case discourages condensation on the circuit board; Weathermatic’s guidance likewise keeps its controller powered and set to system off. With a pump, Rain Bird unplugs an indoor controller, because a power surge could restart a pump that has no water. A hard-wired outdoor controller is an electrician’s or contractor’s job: Rain Bird’s own guide warns that touching the high-voltage wires can cause shock and says power may be turned off only at the breaker panel.
Leave it alone until spring
Tell everyone who manages the lawn that the system is shut down and why. Skip the test cycle in midwinter, which would refill the lines you just emptied. Plan the spring startup for after the hard-freeze risk has passed, and let whoever recommissions the system know about any beds or heads you changed. For related watering topics, see our irrigation guides.
Written from manufacturer and retailer information and general garden practice. GardenHelm has not physically tested the products discussed here. How we choose products


